Feature :
The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single
crystal silicon resonant sensor and are suitable to measure liquid, gas, or steam pressure. EJX510A and
EJX530A output a 4 to 20 mA DC signal corresponding to the measured pressure. It also features quick
response, remote setup and monitoring via BRAIN orHART communications, diagnostics, and optional
status output for pressure high/low alarm. The multisensing technology provides the advanced diagnostic
function to detect such abnormalities as an impulse line blockage or heat trace breakage. FOUNDATION
Fieldbus protocol type is also available. All EJX series models in their standard configuration,
with the exception of the Fieldbus type, are certified by TÜV as complying with SIL 2 for safety requirement
Specification :
Ambient Temperature Effects per 28˚C (50˚F)
Change (0.15% of Span + 0.15% of URL)
Stability (All normal operating condition)
0.1% of URL per 1 year
Power Supply Effects